Sham Comparator: Sham
est développé par University of Nottingham.
Le traitement est actuellement en Non applicable.
Il est associé à SEP.
Son objectif thérapeutique principal est Traitement symptomatique.
Le statut actuel est : suivi actif.
À vérifier
Traitement symptomatique
Non applicable
University of Nottingham
United Kingdom
The vagus nerve is a large nerve that runs from the gut to the brain. It consists of two main sections, left and right, and comprises a series of branches. One of these branches runs through the ear. Stimulating the vagus nerve with a stimulation device, either implanted in the body or applied to the skin, has been used to treat a number of health conditions associated with the functioning of the vagus nerve. It has also been explored for tinnitus. Tinnitus is the perception of sound in the absence of an external source. It is believed to be related to abnormal activity in the brain. Stimulation of the vagus nerve may be an effective way of normalising this brain activity, thereby reducing tinnitus.
Two types of vagus nerve stimulation (VNS) have been trialled: 1) invasive VNS, using a surgically implanted vagus nerve stimulator and 2) non-invasive VNS, using electrical stimulation devices that are placed on the skin, near a section of the vagus nerve. Past studies of these techniques show that VNS may be a promising future treatment for tinnitus. However, there is not enough data available to draw a firm conclusion on whether VNS is effective at reducing tinnitus or not. Furthermore, all previous studies of VNS for tinnitus have used electrical stimulation of the vagus nerve. Stimulating the vagus nerve, whether through an implanted device or a device on the skin, comes with serious technical challenges. Most importantly, electric currents follow the path of least resistance. When running through biological tissues, such as skin, cartilage or bone, it is difficult to aim for the part of the body that needs to be stimulated. This means it isn't always easy to tell whether the vagus nerve is indeed being stimulated and how much of the current is actually reaching the vagus nerve.
This problem can be overcome by ultrasound stimulation. Ultrasound stimulation employs high frequency sound waves to stimulate tissue. These soundwaves travel through the human body much more predictably than electric currents. As such, ultrasound stimulation of the vagus nerve may be more effective than electrical stimulation. The ZenBud device is designed to apply ultrasound stimulation to part of the vagus nerve that runs through the ear. Ultrasound stimulation allows for more targeted stimulation, increasing the chance of the stimulation reaching the vagus nerve. The ZenBud device is safe for use in healthy adults and received CE marking based on CE assessments conducted at the University of Nottingham).
A study found that healthy volunteers can't tell whether they're receiving real U-VNS or sham. It also found that adverse effects are mild, short-lasting and are most commonly feelings of pressure, pain, tingling or warming up of the skin where the device sits on the ear. The next step is to see whether these findings are the same in people with tinnitus. This study aims to 1) investigate the effectiveness of blinding of U-VNS vs sham, 2) evaluate the intensity, onset and duration of any adverse effects of U-VNS in people with tinnitus, and 3) assess the acceptability of U-VNS in people with tinnitus.
Ce pourcentage n’est pas une probabilité de succès clinique.
Il mesure uniquement la force de la classification automatique de l’objectif scientifique. Le calcul part de 45 points, ajoute 7 points par unité de poids du mot-clé le plus fortement détecté, puis est plafonné à 95 %. Exemple : un score maximal de 2 donne 45 + (2 × 7) = 59 %.
Ce score est heuristique et doit être vérifié dans le protocole ou une publication.
Aucune incohérence majeure détectée entre la maladie, l’objectif et la description.
Transparence et qualité de la fiche
données vérifiables
ClassificationCohérente automatiquement
Confiance de la fiche100 %
Source principaleSource officielle ou publication indexée
Dernière vérification2026-01-26
Anomalies détectées0
Validation humaineValidation humaine non effectuée
Donnée issue d’une sourceDonnée normalisée automatiquementInterprétation algorithmique
Classification scientifique multi-axes
ne pas confondre statut et résultat
État de l’étudeTerminée
Disponibilité des résultatsRésultats à vérifier
InterprétationImpossible à déterminer
Niveau de preuveNon évaluable
Un essai terminé n’est pas nécessairement positif. Un essai arrêté n’est classé comme échec scientifique que lorsqu’un résultat ou une raison explicite le confirme.
Indicateurs factuels
sans score subjectif
Phase enregistréeNon applicable
Études associées0
Publications associées0
Statut consolidéSuivi actif
Aucune chance de succès, note d’innovation, potentiel thérapeutique ou probabilité de commercialisation n’est calculé tant qu’un modèle validé et des données suffisantes ne sont pas disponibles.
Historique factuel de la molécule
1 événement(s) daté(s)
Cette liste reprend uniquement les dates trouvées dans les registres et publications liés. Elle ne constitue pas une prévision.
Date
Événement
Source
2026-01-26
Dernière mise à jour des donnéesSham Comparator: Sham
Ces sources sont proposées pour vérification. Les informations de la fiche doivent être confirmées dans les registres officiels ou les publications originales.